Mains supply: 230V 50/60Hz. (Max. current TBC) Internal power supply: 13.5V d.c. (400mA max. current when powered by Mains) Max battery size and t...
  • Mains supply: 230V 50/60Hz. (Max. current TBC)
  • Internal power supply: 13.5V d.c. (400mA max. current when powered by Mains)
  • Max battery size and type: 12V 2.1Ah VRLA
  • Auxiliary relays: 2 volt free relay contacts (NO/C/NC). Relay 1 activates on a standard call and pulses on an emergency call; Relay 2 activates on a emergency call. Both relays rated at 500mA @ 12V d.c.
  • Indicators: 30 red Zonal Alarm LEDs. Lit steady for a Standard call, pulse for an Emergency call); Internal buzzer
  • Controls: Optional mute button.
  • Expansion connections: Connections provided for up to 10 repeater panels and 3 remote sounders
  • Product dimensions (mm): 406 x 214 x 98. Surface mounting.
  • Construction & finish: Metal
  • IP Rating: IP41
  • Weight: 2.946kg
  • Operating conditions/temperature: -5 to 40ºC